博科交換機6510異常下電上電后所有端口亮橙色解決辦法


故障現有如圖:

兩個交換機的狀態如下:

----------------------------------------------------------------

SW6510:FID128:admin> switchshow                          ##上面故障交換機
switchName: SW6510
switchType: 109.1
switchState: Offline (Persistent)                                  ##故障交換機這里顯示離線
switchMode: Native
switchRole: Disabled
switchDomain: 1 (unconfirmed)
switchId: fffc01
switchWwn: 10:00:c4:f5:7c:aa:a1:27
zoning: OFF
switchBeacon: OFF
FC Router: OFF
HIF Mode: OFF
Allow XISL Use: OFF
LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Ficon Switch: N o, Address Mode 0]

Index Port Address Media Speed State Proto
==================================================

SW6510:FID128:admin> switchshow                    ##下面正常交換機
switchName: SW6510
switchType: 109.1
switchState: Online                                               ##正常交換機這里顯示在線                                            
switchMode: Native
switchRole: Principal
switchDomain: 1
switchId: fffc01
switchWwn: 10:00:88:94:71:3f:a7:7d
zoning: OFF
switchBeacon: OFF
FC Router: OFF
HIF Mode: OFF
Allow XISL Use: OFF
LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Ficon Switch: N o, Address Mode 0]

Index Port Address Media Speed State Proto
==================================================

 

故障處理方法

登錄交換機執行下面兩個命令

SW6510:FID128:admin> switchcfgpersistentenable         ##第一條命令,使用switchcfgpersistentenable將switch的persisten狀態設置為enable,這樣下次重啟后,switch的狀態是enable。 
Switch's persistent state set to 'enabled'                            ##已經提示為激活

 

SW6510:FID128:admin> switchenable                            ##第二條命令,這條命令不執行應該也可以,這條命令是啟用交換機

 

網上說出現這個的原因如下:

switchState: Offline (Persistent),說明您交換機狀態不對,需要使用命令switchcfgpersistentenable開啟端口即可,出現這種情況很有可能是異常下電了光交,在上電后可能會概率導致交換機進入persistentdisable狀態。

 