[轉]iMPACT Spartan-6 FPGA - "WARNING:iMPACT:2217-Error shows in the status register, CRC Error bit is Not 0"


AR# 45304

iMPACT Spartan-6 FPGA - "WARNING:iMPACT:2217-Error shows in the status register, CRC Error bit is Not 0"

https://www.xilinx.com/support/answers/45304.html

 

Description

If I program a Spartan-6 device using iMPACT, the following message occurs:

WARNING:iMPACT:2217-Error shows in the status register, CRC Error bit is Not 0

Configuration completes successfully and DONE goes High on the board.

Why does this message appear?

Solution

If you have "Security Level = 1" or "Security Level = 0" set in your BitGen options, then you might see this warning.

For Spartan-6 FPGA:

Security level: 

  • Level0: SBITS=00: R/W OK (default)
  • Level1: SBITS=01: Permits only ICAP readback
  • Level2: SBITS=10: All readback disabled

 

The status register is covered by this security setting as it is a config register.

It is expected that it will not be readable with security set, so this warning is flagged.

The warning can be ignored if you have these settings.


免責聲明!

本站轉載的文章為個人學習借鑒使用,本站對版權不負任何法律責任。如果侵犯了您的隱私權益,請聯系本站郵箱yoyou2525@163.com刪除。



 
粵ICP備18138465號   © 2018-2025 CODEPRJ.COM