DELL遠程卡 racadm常用命令



racadm常用子命令:
硬件資源:

  • 獲取內存大小: racadm get BIOS.memSettings.SysMemSize 
  • 獲取內存工作速率: racadm get BIOS.MemSettings.SysMemSpeed
  • 獲取內存類型: racadm get BIOS.MemSettings.SysMemType


BIOS相關:

  • 錯誤提示狀態:racadm get BIOS.MiscSettings.ErrPrompt
  • 關閉錯誤提示: racadm set BIOS.MiscSettings.ErrPrompt Disabled
  • BIOS啟動模式: racadm get BIOS.BiosBootSettings.BootMode(默認BIOS,另有UEFI)
  • 系統啟動順序: racadm get BIOS.BiosBootSettings.BootSeq 
  • 更改系統啟動順序:racadm set BIOS.BiosBootSettings.BootSeq NIC.Integrated.1-1-1,HardDisk.List.1-1,Optical.SATAEmbedded.E-1 
  • 提交BIOS objects job:jobqueue create BIOS.Setup.1-1
  • 獲取sn: racadm get BIOS.SysInformation.SystemServiceTag
  • 獲取型號: racadm get BIOS.SysInformation. SystemModelName
  • 獲取bios版本: racadm get BIOS.SysInformation. SystemBiosVersion


網卡相關:

  • 獲取網卡mac: racadm getsysinfo -s ( racadm nicstatistics | racadm racdump )
  • 獲取網卡3是否開啟pxe:racadm get nic.NICConfig.3.LegacyBootProto
  • 啟用網卡pxe: racadm set nic.NICConfig.3.LegacyBootProto PXE
  • PXE配置應用生效: racadm jobqueue create NIC.Integrated.1-3-1
  • 提交NIC objects job:racadm jobqueue create NIC.Integrated.1-1 -r pwrcycle -s TIME_NOW -e 20120501100000


磁盤相關:

  • 獲取物理磁盤: racadm storage get pdisks
  • 獲取虛擬磁盤信息: storage get vdisks -o [ -p status,size,layout,state ]


raid相關:

  • 獲取raid控制器: racadm storage get controllers
  • 獲取raid控制器屬性name、status: racadm storage get controllers -o -p name,status
  • 刪除所有raid: racadm storage resetconfig:RAID.Integrated.1-1
  • 提交storage作業: racadm jobqueue create RAID.Integrated.1-1 -s TIME_NOW -r none ( forced | pwrcycle | graceful) [ -—realtime ]
  • 創建raid5,分配300G做系統: racadm storage createvd:RAID.Integrated.1-1 -rl r5 -size 300g -pdkey:Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1,Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1,Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1
  • 創建raid5: racadm storage createvd:RAID.Integrated.1-1 -rl r5 -pdkey:Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1,Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1,Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1


用戶相關:

  • 注:數字2、15為用戶ID。
  • 查看用戶信息:racadm get idrac.users.2
  • 添加用戶:racadm set idrac.users.15.username chenss
  • 設置密碼:racadm set idrac.users.15.password wuyancs
  • 設置為idrac管理員:racadm set idrac.users.15.Privilege 0x1ff
  • 啟用用戶:racadm set idrac.users.15.enable enabled


IP相關:

  • 獲取idrac ip info: racadm get iDRAC.IPv4[ Address | Static | Gateway ]


日志相關:
獲取前置面板LCD顯示信息:racadm get System.LCD.CurrentDisplay 

系統相關:

  • 開機: racadm serveraction powerup
  • 關機: racadm serveraction powerdown
  • 重啟: racadm serveraction powercycle
  • 狀態: racadm serveraction powerstatus
  • 獲取idrac snap info:racadm get iDRAC.SNMP


備注:提交作業時,perc8的卡(H710)是不支持realtime參數的;realtime參數是從perc9(H730)才開始支持。