引言:之前因為沒有配置過FC交換機,所以對命令不是很熟悉,甚至都沒有配置管理地址。導致在后來在處理故障中遇到了問題
因為網上能找到的命令有限,我就寫一些本次故障中常使用的一些命令
1.查看配置的管理IP地址
SW6510:admin> ipaddrshow
SWITCH
Ethernet IP Address: 172.17.10.7
Ethernet Subnetmask: 255.255.255.0
Gateway IP Address: 172.17.10.1
DHCP: Off
2.查看交換機license-id
SW6510:admin> licenseidshow
3.配置管理IP地址
SW6510:admin> ipaddrset
4.查看交換機os版本信息
SW6510:admin> version
Kernel: 2.6.14.2
Fabric OS: v8.0.2c
Made on: Tue May 30 17:37:59 2017
Flash: Fri Sep 14 20:58:34 2018
BootProm: 1.0.11
5.查看交換機狀態
SW6510:admin> switchshow
switchName: SW6510
switchType: 109.1
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 1
switchId: fffc01
switchWwn: 10:00:88:94:71:61:4f:6f
zoning: OFF
switchBeacon: OFF
FC Router: OFF
FC Router BB Fabric ID: 128
Address Mode: 0
HIF Mode: OFF
Index Port Address Media Speed State Proto
==================================================
0 0 010000 id N16 No_Light FC
1 1 010100 id N16 Online FC F-Port 10:00:00:10:9b:43:8c:50
2 2 010200 id N16 Online FC F-Port 10:00:00:10:9b:43:88:56
3 3 010300 id N16 Online FC F-Port 10:00:00:10:9b:43:85:74
6.修改密碼
SW6510:admin> passwd
博科默認的用戶名:admin 密碼:password
7.查看端口錯誤狀態
SW6510:admin> porterrshow
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
0: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
1: 330 640 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
2: 328 638 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
3: 259.8k 3.7m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
4: 4.1m 2.7m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
5: 2.0m 1.3m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
6: 2.1m 1.3m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
7: 2.0m 1.3m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
8: 1.1m 842.3k 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9: 2.1m 1.5m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
10: 2.7m 1.8m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
11: 7.6k 1.7k 0 0 0 0 0 0 0 0 2 0 2 0 0 0 0 0 0
重點關注:link fail、loss sync、loss sig這3個參數的值
8.清除porterrshow的數據
SW6510:admin>stateclear
9.查看錯誤日志
SW6510:admin>errdump
10.健康自檢測命令
SW6510:admin>mapsdb --show
遇到的問題,服務端報警ipfc有頻繁的閃斷,但是查看交換機errdump日志沒有告警,通過健康自檢測命令也沒有日志記錄。詢問廠家的支撐,端口頻繁的up/down有可能不會寫入到errdump日志當中,需要用porterrshow命令來觀察,主要是觀察上面說到的三個重要參數是否有變化。