redis setinel 啟動就 sdown


 

剛啟動檢測正常后就其他節點都 sdown ,每個節點都是一樣的報錯,報下面的錯:

 

10908:X 22 Mar 16:33:46.571 # WARNING: The TCP backlog setting of 511 cannot be enforced because /proc/sys/net/core/somaxconn is set to the lower value of 128.
10908:X 22 Mar 16:33:46.576 # Sentinel ID is 0567d030532d64e9983ea318b91c465c5e6ae446
10908:X 22 Mar 16:33:46.576 # +monitor master mymaster 192.168.21.241 6379 quorum 3
10908:X 22 Mar 16:33:46.577 * +slave slave 192.168.21.242:6379 192.168.21.242 6379 @ mymaster 192.168.21.241 6379
10908:X 22 Mar 16:33:46.579 * +slave slave 192.168.21.244:6379 192.168.21.244 6379 @ mymaster 192.168.21.241 6379
10908:X 22 Mar 16:33:47.815 * +sentinel sentinel ed36ffb02a686db2c306dc49200bf36af0f0b823 192.168.21.241 26379 @ mymaster 192.168.21.241 6379
10908:X 22 Mar 16:33:48.159 * +sentinel sentinel 011a32fae263fc160b695cb09e72f4e5d4accde5 192.168.21.242 26379 @ mymaster 192.168.21.241 6379
10908:X 22 Mar 16:34:16.665 # +sdown slave 192.168.21.244:6379 192.168.21.244 6379 @ mymaster 192.168.21.241 6379
10908:X 22 Mar 16:34:17.825 # +sdown sentinel ed36ffb02a686db2c306dc49200bf36af0f0b823 192.168.21.241 26379 @ mymaster 192.168.21.241 6379
10908:X 22 Mar 16:34:18.195 # +sdown sentinel 011a32fae263fc160b695cb09e72f4e5d4accde5 192.168.21.242 26379 @ mymaster 192.168.21.241 6379

 

 

這兩個參數是必須開啟的:

protected-mode no

daemonize yes

 


免責聲明!

本站轉載的文章為個人學習借鑒使用,本站對版權不負任何法律責任。如果侵犯了您的隱私權益,請聯系本站郵箱yoyou2525@163.com刪除。



 