一,配置ipmi
yum -y install OpenIPMI OpenIPMI-devel ipmitool freeipmi
登入IDARAC
在服務端測試是否可以獲得數據
ipmitool -I lanplus -H (ip) -U root -P (password) -L USER sdr
#打印傳感器倉庫中的任何監控項和從傳感器讀取到的值
ipmitool -I lanplus -H (ip) -U root -P (password) -L USER sensor
#打印傳感器信息。
配置zabbix
注:為了支持IPMI,需要在zabbix server/proxy安裝時增加--with-openipmi參數
服務器端配置zabbix IPMI pollers
zabbix_server.conf/zabbix_proxy.conf
sed -i '/# StartIPMIPollers=0/aStartIPMIPollers=5' zabbix_server.conf systemctl restart zabbix-server
模板 導入: https://share.zabbix.com/cat-server-hardware/template-ipmi-dell-poweredge-r510
ipmitool -I lan -H 10.103.1.100 -U root -P calvin -L user sensor list # ipmitool -I lan -H 10.103.1.100 -U root -P calvin -L user sensor get "FAN MOD 1B RPM"
作者:ygqygq2
鏈接:https://www.jianshu.com/p/819d5fea1cfa
來源:簡書
簡書著作權歸作者所有,任何形式的轉載都請聯系作者獲得授權並注明出處。
ipmitool -I lan -H 10.103.1.100 -U root -P calvin -L user sensor list # ipmitool -I lan -H 10.103.1.100 -U root -P calvin -L user sensor get "FAN MOD 1B RPM"
作者:ygqygq2
鏈接:https://www.jianshu.com/p/819d5fea1cfa
來源:簡書