LoadRunner中InvokeMethod failure: 外部組件發生異常解決辦法


-82801 abnormal termination,caused by mdrv process termination


-29996
error:process mmdrv.exe was not created .reason:系統資源不足,無法完成請求的服務。


-29994
error:one thread was not created.reason:句柄無效


-27727 Acttion.c [29]:step
download timeout[600 seconds] has expired when downloading resources.set the
"step timeout caused by resource is warning", run-time setting to yes/no to have
this message as a warning /error,respectively


-84817 failed to initialize reason:timeout

 

 

使用loadrunner壓測webservice接口,時,遇到這樣一個問題。

線程模式:

運行幾分鍾后主線程退出

Abnormal termination, caused by mdrv process termination 

Action.c(6): Error: Web service call "submitNLSMSRequest_101" execution failed

Action.c(6): Error: InvokeMethod failure: 外部組件發生異常。.

Action.c(6): Error: ExtractResultArg failure: 外部組件發生異常。.

Failed to Stop. Reason: TimeOut

Action.c(6): Error: C interpreter run time error: Action.c (6):  Error -- memory violation : Exception ACCESS_VIOLATION received.

改用進程模式

運行幾分鍾后報錯:Runtime Error!

Program:E:\LoadRunner\bin\mmdrv.exe

R6025

- pure virtual fuction call

 

解決總結:

1.采用進程模式

2.設置進程最大進程數,20或10(D:\Program Files\HP\LoadRunner\config\D:\Program Files\HP\LoadRunner\configd的AgentMaxThreadsPerDriver修改為10)

3.負載

4.較少日志輸出、添加思考時間


免責聲明!

本站轉載的文章為個人學習借鑒使用,本站對版權不負任何法律責任。如果侵犯了您的隱私權益,請聯系本站郵箱yoyou2525@163.com刪除。



 