转 OGG-01224 TCP/IP error 111 (Connection refused); retries exceeded.


https://blog.csdn.net/yabingshi_tech/article/details/40620351

 

在源端启动goldengate pump进程,状态起初是running,后来却变成了ABENDED    

  1.  
    GGSCI (source_pc) 3> info all
  2.  
     
  3.  
    Program Status Group Lag at Chkpt Time Since Chkpt
  4.  
     
  5.  
    MANAGER RUNNING
  6.  
    EXTRACT RUNNING EORA_T1 00:00:00 00:00:07
  7.  
    EXTRACT ABENDED PORA_T1 00:00:00 00:12:40
  8.  
     
  9.  
     


查看错误报告:

GGSCI (source_pc) 4> view report pora_t1

看到这个错误:

2014-10-30 03:02:25  ERROR   OGG-01224  TCP/IP error 111 (Connection refused); retries exceeded.

2014-10-30 03:02:25  ERROR   OGG-01668  PROCESS ABENDING. 

--查看pump参数

  1.  
    GGSCI (source_pc) 5> view params pora_t1
  2.  
     
  3.  
    extract pora_t1
  4.  
     
  5.  
    setenv (NLS_LANG=AMERICAN_AMERICA.AL32UTF8)
  6.  
     
  7.  
    passthru
  8.  
     
  9.  
    rmthost 192.168.8.226,mgrport 7809
  10.  
     
  11.  
    rmttrail ./dirdat/pa
  12.  
     
  13.  
    table scott.t;
  14.  
     
  15.  
     
  16.  
     

 --查看源端和目标端mgr参数

  1.  
    GGSCI (source_pc) 6> view params mgr
  2.  
     
  3.  
    PORT 7089
  4.  
     
  5.  
     
  6.  
     
  7.  
     
  8.  
    GGSCI (target_pc) 10> view params mgr
  9.  
     
  10.  
    PORT 7089
  11.  
     
  12.  
     

发现它们的端口号不一致.

改成一样的,如都改为7809,然后重启mgr,pump,extract,replicat等相关进程即可

 